THERMO KING TRUCK, TRAILER, CR AND DAS ALARM CODES

 

THIS DOCUMENT SHOWS ALL CURRENT TRUCK, TRAILER, CR AND DAS ALARM CODES. NOT ALL CODES ARE POSSIBLE ON ALL UNITS.

 

IF THE ALARM APPLIES TO A MULTI-TEMP ZONE, THAT ZONE WILL BE IDENTIFIED.

 

BE SURE TO RECORD ALL ALARMS THAT OCCUR. THEY ARE VALUABLE TO THE SERVICE TECHNICIAN.

 

ALARM CODE NUMBERS MARKED WITH PARTENTHESIS (XX) MAY EXIST WITH ALARM CODE 84 AND MAY CLEAR AUTOMATICALLY.

 

COLOR CODE DEFINITIONS OK TO RUN CHECK AS SPECIFIED TAKE IMMEDIATE ACTION

 

THESE ARE SUGGESTIONS ONLY. ALWAYS CONSULT YOUR COMPANY FOR FINAL DECISIONS.

 

Num Color Description Operator Action

 

00

 

 

 

No Alarms Exist No action required.

 

 

Check Evaporator Coil Sensor Manually monitor temperature. Report alarm at end of day.

 

 

Check (Control) Return Air Sensor Manually monitor temperature. Report alarm at end of day.

 

 

Check (Control) Discharge Air Sensor Manually monitor temperature. Report alarm at end of day.

 

 

Check Ambient Temp Sensor Report alarm at end of day.

 

 

Check Coolant Temp Sensor Report alarm at end of day.

 

 

Check Engine RPM Sensor Report alarm at end of day.

 

 

Unit Running on Coil Sensor Manually monitor temperature. Report alarm at end of day.

 

 

High Evaporator Temperature If unit/zone is shut down repair immediately. Otherwise, report alarm at end of day.

 

 

High Discharge Pressure (or Temperature) If unit/zone is shut down repair immediately. Otherwise, report alarm at end of day.

 

 

Unit or Zone Controlling on Alternate Sensor Manually monitor temperature. Report alarm at end of day.

 

 

Sensor or Digital Input Shutdown Unit/zone cannot operate and is shut down. Repair immediately.

 

 

Sensor Check Manually monitor temperature. Report alarm at end of day.

 

 

Defrost Terminated by Time Report alarm at end of day.

 

 

Check Glow Plugs or Intake Air Heater If unit/zone is shut down repair immediately. Otherwise, report alarm at end of day.

 

 

Manual Start Not Completed Report alarm at end of day.

 

 

Engine Failed to Crank If unit/zone is shut down repair immediately. Otherwise, report alarm at end of day.

 

 

High Engine Coolant Temperature If unit/zone is shut down repair immediately. Otherwise, report alarm at end of day.

 

 

Low Engine Oil Pressure If unit/zone is shut down repair immediately. Otherwise, report alarm at end of day.

 

 

Engine (Vapor Motor CR) Failed to Start If unit/zone is shut down repair immediately. Otherwise, report alarm at end of day.

 

 

Cooling Cycle Check Manually monitor temperature. Report alarm at end of day.

 

 

Heating Cycle Check Manually monitor temperature. Report alarm at end of day.

 

 

Cooling Cycle Fault Unit/zone cannot operate and is shut down. Repair immediately.

 

 

Heating Cycle Fault Unit/zone cannot operate and is shut down. Repair immediately.

 

 

Alternator Check If unit/zone is shut down repair immediately. Otherwise, report alarm at end of day.

 

 

Check Refrigeration Capacity Manually monitor temperature. Report alarm at end of day.

 

 

Vapor Motor RPM High (CR) Unit/zone cannot operate and is shut down. Repair immediately.

 

 

Pretrip or Self Check Abort Report alarm at end of day.

 

 

Defrost Damper Circuit Check Manually monitor temperature. Report alarm at end of day.

 

 

Defrost Damper Stuck Closed Unit/zone cannot operate and is shut down. Repair immediately.

 

 

Check Oil Pressure Switch If unit/zone is shut down repair immediately. Otherwise, report alarm at end of day.

 

 

Refrigeration Capacity Low Unit/zone cannot operate and is shut down. Repair immediately.

 

 

Check Engine RPM Report alarm at end of day.

 

 

Check Modulation Circuit Manually monitor temperature. Report alarm at end of day.

 

 

Check Run Relay Circuit Unit/zone cannot operate and is shut down. Repair immediately.

 

 

Electric Motor Failed to Run If unit/zone is shut down repair immediately. Otherwise, report alarm at end of day.

 

 

Check Engine Coolant Level Report alarm at end of day.

 

 

Electric Phase Reversed If unit/zone is shut down repair immediately. Otherwise, report alarm at end of day.

 

 

Check Water Valve Circuit Manually monitor temperature. Report alarm at end of day.

 

 

Check High Speed Circuit If unit/zone is shut down repair immediately. Otherwise, report alarm at end of day.

 

 

Check Engine Coolant Temp Report alarm at end of day.

 

 

Unit Forced to Low Speed Report alarm at end of day.

 

 

Unit Forced to Low Speed Modulation Report alarm at end of day.

 

 

Check Fuel System Add fuel as necessary. Otherwise, report alarm at end of day.

 

 

Check Hot Gas or Hot Gas Bypass Circuit If unit/zone is shut down repair immediately. Otherwise, report alarm at end of day.

 

 

Check Air Flow Manually monitor temperature. Report alarm at end of day.

 

 

Remote Sensor Shutdown Unit/zone cannot operate and is shut down. Repair immediately.

 

 

Check Belts or Clutch If unit/zone is shut down repair immediately. Otherwise, report alarm at end of day.

 

 

Check Spare Sensor 1 Report alarm at end of day.

 

 

Reset Clock Report alarm at end of day.

 

 

Check Shutdown Circuit If unit/zone is shut down repair immediately. Otherwise, report alarm at end of day.

 

 

Check Heat Circuit If unit/zone is shut down repair immediately. Otherwise, report alarm at end of day.

 

 

Check Economizer Valve Circuit If unit/zone is shut down repair immediately. Otherwise, report alarm at end of day.

 

 

Test Mode Timeout Clear alarm and restart unit.

 

 

Check Engine Speeds Report alarm at end of day.

 

 

Low Battery Voltage If unit/zone is shut down repair immediately. Otherwise, report alarm at end of day.

 

 

Ammeter Out of Calibration Unit/zone cannot operate and is shut down. Repair immediately.

 

 

Engine or Vapor Motor Stopped If unit/zone is shut down repair immediately. Otherwise, report alarm at end of day.

 

 

Pretrip Reminder Report alarm at end of day.

 

 

Abnormal Temperature Differential If unit/zone is shut down repair immediately. Otherwise, report alarm at end of day.

 

 

Low Engine Oil Level If unit/zone is shut down repair immediately. Otherwise, report alarm at end of day.

 

 

Check Liquid Line Solenoid Circuit If unit/zone is shut down repair immediately. Otherwise, report alarm at end of day.

 

 

Internal Controller Fault Code If unit/zone is shut down repair immediately. Otherwise, report alarm at end of day.

 

 

Hourmeter Failure Report alarm at end of day.

 

 

Hourmeter 4 Exceeds Set Time Limit Report alarm at end of day.

 

 

Hourmeter 5 Exceeds Set Time Limit Report alarm at end of day.

 

 

Hourmeter 6 Exceeds Set Time Limit Report alarm at end of day.

 

 

Controller Reset to Defaults Report alarm at end of day.

 

 

Controller RAM Failure If unit/zone is shut down repair immediately. Otherwise, report alarm at end of day.

 

 

Controller EPROM Failure If unit/zone is shut down repair immediately. Otherwise, report alarm at end of day.

 

 

Controller EPROM Checksum Failure If unit/zone is shut down repair immediately. Otherwise, report alarm at end of day.

 

 

Data Log EPROM Failure If unit/zone is shut down repair immediately. Otherwise, report alarm at end of day.

 

 

Internal Data Logger Overflow Report alarm at end of day.

 

 

Check Compressor Temp Sensor Report alarm at end of day.

 

 

High Compressor Temp If unit/zone is shut down repair immediately. Otherwise, report alarm at end of day.

 

 

High Compressor Temp Shutdown Unit/zone cannot operate and is shut down. Repair immediately.

 

 

Low Engine Coolant Temp Report alarm at end of day.

 

 

Restart Null Report alarm at end of day.

 

 

Forced Unit Operation Report alarm at end of day.

 

 

Check Discharge Pressure Sensor Report alarm at end of day.

 

 

Check Suction Pressure Sensor Report alarm at end of day.

 

 

Reserved for CR

 

 

Check Electronic Throttling Valve Circuit If unit/zone is shut down repair immediately. Otherwise, report alarm at end of day.

 

 

Electric Overload If unit/zone is shut down repair immediately. Otherwise, report alarm at end of day.

 

 

Check Electric Ready Input If unit/zone is shut down repair immediately. Otherwise, report alarm at end of day.

 

 

Sensor Grades Not Set If unit/zone is shut down repair immediately. Otherwise, report alarm at end of day.

 

 

Low Compressor Suction Pressure If unit/zone is shut down repair immediately. Otherwise, report alarm at end of day.

 

 

Check Loader #1 Circuit If unit/zone is shut down repair immediately. Otherwise, report alarm at end of day.

 

 

Check Loader #2 Circuit If unit/zone is shut down repair immediately. Otherwise, report alarm at end of day.

 

 

Low Fuel Level Add fuel as required.

 

 

Failed Remote Return Air Sensor (CR) If unit/zone is shut down repair immediately. Otherwise, report alarm at end of day.

 

 

Check Fuel Level Sensor Report alarm at end of day.

 

 

High Compressor Pressure Ratio If unit/zone is shut down repair immediately. Otherwise, report alarm at end of day.

 

 

Heater Fan Failure (CR) If unit/zone is shut down repair immediately. Otherwise, report alarm at end of day.

 

 

Controlling on Evap Coil Outlet Temp (CR) Manually monitor temperature. Report alarm at end of day.

 

 

Low Evaporator Coil Temperature (CR) If unit/zone is shut down repair immediately. Otherwise, report alarm at end of day.

 

 

Low Heater Fuel Level (CR) Manually monitor temperature. Report alarm at end of day.

 

 

Check Remote Fan Speed Manually monitor temperature. Report alarm at end of day.

 

 

Check Receiver Tank Press Sol Circuit If unit/zone is shut down repair immediately. Otherwise, report alarm at end of day.

 

 

Check Purge Valve Circuit If unit/zone is shut down repair immediately. Otherwise, report alarm at end of day.

 

 

Check Condenser Inlet Sol Circuit If unit/zone is shut down repair immediately. Otherwise, report alarm at end of day.

 

 

Door Open Timeout Close doors. Report alarm at end of day.

 

 

Check High Discharge Pressure Sensor Replaced by Alarm Code 86

 

 

Check Suction Line Sol Circuit If unit/zone is shut down repair immediately. Otherwise, report alarm at end of day.

 

 

Unit Not Configured Correctly Report alarm at end of day.

 

 

Check Remote Fans If unit/zone is shut down repair immediately. Otherwise, report alarm at end of day.

 

 

Check Electric Heat Circuit Manually monitor temperature. Report alarm at end of day.

 

 

Multiple Alarms - Can Not Run Unit/zone cannot operate and is shut down. Repair immediately.

 

 

Check High Pressure Cut Out Switch If unit/zone is shut down repair immediately. Otherwise, report alarm at end of day.

 

 

Check High Pressure Cut In Switch Report alarm at end of day.

 

 

Auto Switch from Diesel to Electric Normal operation – does not affect performance.

 

 

Auto Switch from Electric to Diesel Normal operation – does not affect performance.

 

 

Reserved for CR

 

 

Check Alternator Excite Circuit If unit/zone is shut down repair immediately. Otherwise, report alarm at end of day.

 

 

Check PMW Liquid Injection Circuit If unit/zone is shut down repair immediately. Otherwise, report alarm at end of day.

 

 

Check Diesel/Electric Circuit If unit/zone is shut down repair immediately. Otherwise, report alarm at end of day.

 

 

Check Evap Coil Inlet Temp Sensor (CR) Manually monitor temperature. Report alarm at end of day.

 

 

Check Evap Coil Outlet Temp Sensor (CR) Report alarm at end of day.

 

 

Check Tank Level Sensor (CR) If unit/zone is shut down repair immediately. Otherwise, report alarm at end of day.

 

 

Check Back Pressure Regulator (CR) Manually monitor load temperature. Report this alarm at the end of the day.

 

 

Setpoint Not Entered Be sure setpoint is adjusted to required temperature.

 

 

Engine Run Time Maint Reminder #1 Report alarm at end of day.

 

 

Engine Run Time Maint Reminder #2 Report alarm at end of day.

 

 

Electric Run Time Maint Reminder #1 Report alarm at end of day.

 

 

Electric Run Time Maint Reminder #2 Report alarm at end of day.

 

 

Total Unit Run Time Maint Reminder #1 Report alarm at end of day.

 

 

Total Unit Run Time Maint Reminder #2 Report alarm at end of day.

 

 

Controller Power On Hours Report alarm at end of day.

 

 

Check Spare Digital Inputs Report alarm at end of day.

 

 

Check Spare Digital Outputs Report alarm at end of day.

 

 

Check Damper Motor Heater Output If unit/zone is shut down repair immediately. Otherwise, report alarm at end of day.

 

 

Log DAS Real Time Clock Battery Failure (DAS) Report alarm at end of day.

 

 

Abort Evacuation Mode Report alarm at end of day.

 

 

Not currently used

 

 

Auto Switch Diesel to Electric Disabled If unit/zone is shut down repair immediately. Otherwise, report alarm at end of day.

 

 

Check Thermax Valve If unit/zone is shut down repair immediately. Otherwise, report alarm at end of day.

 

 

Check Remote Zone Drain Hose Heater Output Report alarm at end of day.

 

 

Lost CAN Communications to Expansion Module Unit/zone cannot operate and is shut down. Repair immediately.

 

 

Lost Controller ON Feedback Signal If unit/zone is shut down repair immediately. Otherwise, report alarm at end of day.

 

 

Software Version Mismatch Report alarm at end of day.

 

 

Check Multi-Temp Fan Speed Control Output Manually monitor load temperature. Report this alarm at the end of the day.

 

 

Auto Switch Electric to Diesel Disabled If unit/zone is shut down repair immediately. Otherwise, report alarm at end of day.

 

 

Alarm Not Identified If unit/zone is shut down repair immediately. Otherwise, report alarm at end of day.

 

 

Sensor Out of Range Low (DAS and HMI) Report alarm at end of day.

 

 

Sensor Out of Range High (DAS and HMI) Report alarm at end of day.

 

 

DAS Failed Sensor (DAS) Report alarm at end of day.

 

 

Expansion Module Flash Load Failure Report alarm at end of day.

 

 

Low Suction Pressure Switch Failure If unit/zone is shut down repair immediately. Otherwise, report alarm at end of day.

 

 

Lost CAN Communications to HMI Unit/zone cannot operate and is shut down. Repair immediately.

 

 

Check Suction/Liquid Heat Exchanger Bypass Valve If unit/zone is shut down repair immediately. Otherwise, report alarm at end of day.

 

 

OptiSet Plus Profile Mismatch Report alarm at end of day.

 

 

Primary Software Failed to Load Report alarm at end of day.

 

 

Check Battery Condition Report alarm at end of day.

 

 

Lost CAN Communications to Radio Expansion Board Report alarm at end of day.

 

 

Log DAS Real Time Clock Invalid (DAS) Report alarm at end of day.

 

 